Early detection and quick response time help minimize and prevent damage
State-of-the-art Electronic Overload Protection System (EOLP) actively monitors applied torque through the stroke and hydraulic pressure to prevent an over tonnage condition
While traditional overload systems are effective in monitoring maximum tonnage, AIDA's EOLP works throughout the entire stroke of the press
The PLC monitors the pressure and torque throughout the stroke, every 3 msecs
If the pressure exceeds the rated tonnage curve, the servo motor applies reverse torque to stop and reverse the slide
Redundant hydraulic unsticker device provides additional protection and ease of resetting press after an overload condition